All electrical connections are made using the PCB connector on the power shunt. The shunt is connected to the monitor via a standard RJ12 telephone cable. Included in delivery: RJ12 cable (10 m) and battery cable with fuse (2 m); No further components are required. A damaged cell or battery can destroy an entire large, expensive battery bank. If batteries are connected in series, a timely warning message can be generated by measuring the midpoint voltage. Please also note the BMV manual, section 5.2 for further information. After shutdown due to low voltage, the capacity reserve of a lithium-ion battery is approximately 1 Ah per 1000 Ah of battery capacity. The battery will be damaged if the remaining reserve capacity is drained from the battery. For example, a residual current of 10 mA ca.