Hydraulic Single Overcentre Valves For OMS Danfoss Motors, VBCDF 1/2" SE

USE AND OPERATION: These valves are used to control the motor rotation and block it in one direction. In order to have the load under control and avoid its inertia being carried away the valve will prevent any cavitation. Direct flange is ideal for Danfoss type OMS motors and provides maximum safety, very low pressure drops and robust installation. MATERIALS AND FEATURES: Body: zinc-plated steel. Internal parts: hardened and ground steel. Seals: BUNA N standard. Leakage: negligible leakage. Standard setting: 320 Bar. Valve setting must be at least 1.3 times more than load pressure in order to enable the valve to close even when subjected to the maximum load pressure. CONNECTIONS: Connect V1 and V2 to the supply, C1 to the free flow side of the motor and C2 to the motor's side.